Configuration Manager (SCCM) | OSD | Multiple Hard Drives | Basic
Trying to deploy Windows OS through Microsoft Endpoint Configuration Manager and having the issues with the Operating Systems randomly choosing what hard drive to install on, or you just want to take control and decide what hard disk the Operating System should be installed on
Well here are steps to overcome that. Have made life very easy, it is just a few simple steps that need to be added.
The script will identify the total number of Physical Disks excluding ‘BusType’ USB and order by ‘Size’ – smallest to largest. So for anyone using Boot Media it is not going to detect your USB drive as a Physical Disk and wipe it
The default configuration sets the ‘smallest’ sized hard drive as the Primary Disk and formats the remaining drives as simple data drives, taking into account GPT and MBR partitions and initialising any raw disks
The Configuration Manager variable ‘OSDDiskIndex’ will be assigned the disk number of the ‘Primary Disk’ and used in the deployment step ‘Partition Disk 0 – BIOS’ or ‘Partition Disk 0 – UEFI’, ‘Pre-provsion BitLocker’ and Apply Operating System.
More information on the CM variable OSDDiskIndex:
https://docs.microsoft.com/en-us/mem/configmgr/osd/understand/task-sequence-variables#OSDDiskIndex
Pre-Requisites
To enable the script to run the following optional components will need to be added to your Boot Image – WinPE-EnhancedStorage , WinPE-StorageWMI), Microsoft .NET (WinPE-NetFx and WinPE-PowerShell

- Set Disk and Format – PowerShell Script

Add a ‘Run Powershell Script’ to the task sequence before the step ‘Partition Disk’.
Type: Run PowerShell Script
Edit Script: Copy and Paste PowerShell script
PowerShell Execution Policy: Bypass
<#
.WARNING
This script is destructive as it contains Clear-Disk
.SYNOPSIS
Warning Destructive - Created to run in WinPE OSD to Clear-Disk and assign OSDDiskIndex to task sequence Disk Advanced Option Partition Variable
.DESCRIPTION
Runs in WinPE OSD to find all non USB Bus Types, format disk drive(s) and assign smallest disk as OSDDiskIndex variable to be used in the
task sequence
.NOTES
File Name : osddiskcleanbasic.ps1
Website : https://ourcommunityhelper.com
Author : S.P.Drake
Version
1.2 : Exclude unconfigured Intel Optane Memory as valid system disk - https://support.hp.com/gb-en/document/c06692694
1.1 : Added 'No physical disks have been detected' Error Code
1.0 : Initial version
.COMPONENT
(WinPE-EnhancedStorage),Windows PowerShell (WinPE-StorageWMI),Microsoft .NET (WinPE-NetFx),Windows PowerShell (WinPE-PowerShell). Need to
added to the WinPE Boot Image to enable the script to run
The COMObject Microsoft.SMS.TSEnvironment is only available in MDT\SCCM WinPE
#>
# Log file function, just change destaination path if required
Function Write-Log {
[CmdletBinding()]
Param(
[Parameter(Mandatory=$False)]
[ValidateSet("INFO","WARN","ERROR","FATAL","DEBUG")]
[String]
$Level,
[Parameter(Mandatory=$False)]
[string]
$Message,
[Parameter(Mandatory=$False)]
[string]
$logfile = "$($TSEnv.value('_SMSTSLogPath'))\OSD_DiskSearchandClean.log"
)
$Stamp = (Get-Date).toString("yyyy/MM/dd HH:mm:ss")
$Line = "$Stamp $Level $Message"
If($logfile) {
Add-Content $logfile -Value $Line
}
Else {
Write-Output $Line
}
}
# Outer Try Catch
try{
# Create PhysicalDisks array
$physicalDisks = @()
# Import Microsoft.SMS.TSEnvironment
$TSEnv = New-Object -COMObject Microsoft.SMS.TSEnvironment
# Read Task Sequnce Variable _SMSTSBootUEFI and set Partition Style
if ($TSEnv.Value('_SMSTSBootUEFI') -eq $True){$Style = 'GPT'} else {$Style = 'MBR'}
Write-Log -Message "All BusTypes excluding USB are searched"
Write-Log
# Get all physical disks that are not BusType USB or unconfigured Intel Optane Memory and order by size (smallest to largest)
$physicalDisks = Get-PhysicalDisk | Where-Object {($_.Bustype -ne 'USB') -and -not($_.Size -lt 34359738368 -and $_.Model -match 'Intel')} | Sort-Object -Property @{Expression = "Size"; Descending = $False}
# Did we find any matching physical disks ?
if ($physicalDisks.count -eq 0) {
Write-Log -Message "No physical disks have been detected"
Write-Log
Write-Log -Level ERROR -Message "Exit Code 0x0000000F : ERROR_INVALID_DRIVE"
Exit 0xF
}
else {
Write-Log -Message "The following physical disks have been detected: -"
Write-Log
# Display all physical disks that have been found
foreach ($disk in $physicalDisks) {
Write-Log -Message "FriendlyName: $($disk.FriendlyName)"
Write-Log -Message "MediaType: $($disk.MediaType)"
Write-Log -Message "BusType: $($disk.BusType)"
Write-Log -Message "Size: $($disk.Size /1GB)"
Write-Log -Message "DeviceID: $($disk.DeviceID)"
Write-Log
}
}
# Display action to be performed
$firstItem = 0
foreach ($disk in $physicalDisks) {
# Is it the first item in the list ?
if ($firstItem -eq 0){
# Get first physical disk in our list - Ordered by BusType and Size
Write-Log -Message "The physical drive $($disk.FriendlyName) of Bustype $($disk.BusType) and Media Type $($disk.MediaType) on Device ID : $($disk.DeviceId) will be assigned to OSDDiskIndex"
# Assign task sequence variable OSDDiskIndex
$TSEnv.Value('OSDDiskIndex') = $disk.DeviceId
}
else {
Write-Log -Message "The physical drive $($disk.FriendlyName) of Bustype $($disk.BusType) and Media Type $($disk.MediaType) on Device ID : $($disk.DeviceId) will be cleaned and used as a Data Disk"
# If disk is new and Partition Style 'RAW' then Initialize Disk
if (get-disk -Number $disk.DeviceId | Where-Object {$_.PartitionStyle -eq 'RAW'}){Initialize-Disk -Number $disk.DeviceId -PartitionStyle $style}
# Clear disk partition and data
Clear-Disk -Number $disk.DeviceId -RemoveOEM -RemoveData -Confirm:$false
Write-Log -Message "Command: Clear-Disk -Number $($disk.DeviceId) -RemoveOEM -RemoveData -Confirm:$false"
# Initialize-Disk
Initialize-Disk -Number $disk.DeviceId -PartitionStyle $style
Write-Log -Message "Command: Initialize-Disk -Number $($disk.DeviceId) -PartitionStyle $($style)"
# Create and format data disk
New-Partition -DiskNumber $disk.DeviceId -UseMaximumSize -AssignDriveLetter | Format-Volume -FileSystem NTFS -NewFileSystemLabel Data -Confirm:$False
Write-Log -Message "Command: New-Partition -DiskNumber $disk.DeviceId -UseMaximumSize -AssignDriveLetter | Format-Volume -FileSystem NTFS -NewFileSystemLabel Data -Confirm:$False"
Write-Log
}
$firstItem = $firstItem +1
}
}catcH{
Write-Log
Write-Log -Level ERROR -Message $_.Exception.Message
Write-Log
Exit 1
}
- Configure Partition Disk 0 – BIOS

Partition Disk 0 – BIOS : Select the ‘Windows (Primary)’ volume and Set the ‘Advance options Variable’ to ‘OSDisk’.
The variable ‘OSDisk’ will be used in the ‘Apply Operating System’ to ensure the operating system gets applied to the correct hard drive.
NOTE: There is no need to change the ‘Disk number’, as this will be ignored and dynamically assigned in the PowerShell script ‘OSDDiskIndex’
- Configure Partition Disk 0 – UEFI

Partition Disk 0 – UEFI : Select the ‘Windows (Primary)’ volume and Set the ‘Advance options Variable’ to ‘OSDisk’.
The variable ‘OSDisk’ will be used in the ‘Apply Operating System’ to ensure the operating system gets applied to the correct hard drive.
NOTE: There is no need to change the ‘Disk number’, as this will be ignored and dynamically assigned in the PowerShell script ‘OSDDiskIndex’
- Pre-provision BitLocker

Pre-Provision Bitlocker : Under ‘Apply BitLocker to the specified drive’, select the ‘Properties’ tab and change the ‘Destination’ to Logical driver letter stored and ‘Variable name’ to OSDisk
NOTE: The Pre-Provision is applied to the Operating System as the ‘OSDisk’ variable was assigned in the PowerShell script
- Apply Operating System

Apply Operating System : Select the ‘Properties’ tab and change the ‘Destination’ to ‘Logical driver letter stored in a variable‘ and ‘Variable name’ to ‘OSDisk‘
NOTE: The Operating System is applied to the correct Drive as the ‘OSDisk’ variable was assigned in the PowerShell script
Log log file of the actions performed can be found at C:\Windows\CCM\Logs\OSD_DiskSearchandClean.log
Downloadable source files can be found at
https://github.com/Drakey2000/CommunityHelper/tree/master/OSDDiskFormat
and also a more enhanced version, where you can set the BusType priority order in which the Operating System should look to install on can be found at the below link
https://ourcommunityhelper.com/2020/11/24/multiple-disk-build-advanced/
Update : Since writing, Microsoft has enhanced the Task Sequence Step Properties for ‘Format and Partition Disk‘. So check in-out, and maybe you wish to change this script, although as it is will do everything you need in most cases.
This will enable you to use scripts to assign variables to all disks, not just ‘OSDDiskIndex‘ and use the ‘Format and Partition Disk‘ in the Task Sequence to dynamically perform actions
Thanks for this post.
The only thing missing is the information that the WinPE must contain Powershell.
LikeLike
Will get that added this weekend. 👍